NEWS

Equipment

Elements of cleanrooms:

 

оборудование для чистых помещений Laboratory equipment
консоли для чистых помещений Medical supply consoles
мониторинг медгазов Monitoring of medical gases
очистка воздуха

Air cleaning units

чистые зоны Local clean areas
бокс для взвешивания  Box for weightening
Intensive care devices
 ограждающий конструкции для чистых помещений Building envelop
 вентиляция для чистых помещений Ventilation
 управление чистыми помещениями Cleanroom's control system
Контрольно-отключающее устройство  Control-tripping device
Рамповые балонные станции Ramp cylinder-stored unit
 Фильтровентиляционный модуль Filter-fan unit

 

 

Pharmacy

Since 2000 Miass Factory of Medical Equipment has carried out designing and construction of complexes of cleanrooms for different fields of industries. As the base for this direction of activity 15-years-old experience of our factory in creation of cleanrooms for medical units serves...

Ramp Cylinder-Stored Unit

АМС МЗМО/English Version/Production/Production run equipment/Ramp Cylinder-Stored Unit
Allocation:
  • decompression of medical gases for following supplying to the distribution channels of medical gases
  • visual control of gas supply by manometers 

Device:

  • automatic devices supply box
    • metal case with control panel
    • two valves
    • two high pressure reducers
    • pneumatic selector valve with special flexible eyelets for definition of operative and reserve sources
  • collectors
  • copper connections
  • holders for ballons
  • manometers
  • reductor of second stage

Station allows to operate two sourses of medical gas, one of which is operative, another - reserve one. While operative sourse is ending, the pneumatic selector valve is activated and the system switched to the reserve sourse.  Both sourses include pressure cells, connected by the alarm system in case of due notice of pressure fall.

Used reductors of the 2210М seria are designed for pressure up to 220 bar, capacity up to 30 m3/h

Specification:
 
Nominal output pressure, bar
5
Maximal output pressure, bar 10
Operative temperature, ° С -5 to +60
Inaccuracy of manometers, %
1,6
Type of pressure cell connection, F
G1/8 F
Output type connection
G 1/2 M
Diameter of emergency valve
16
Operating time
10 years


Aditional options:
  • signal transmission to the alarm box in case of declension from the operative pressure level

Features:
  • rational expenditure of medical gases 
  • System controls the balloon pressure, that allows to economize of medical staff work time

Ordering variant:
  • ramp cylinder-stored unit of medical gases with the automatic sourses switching unit (write the gas)
  • alarm box